This is an abstract base module for power based energy generator models. It defines shared signals and statistics.
See also: EpEnergyConsumerBase, EpEnergySourceBase, EpEnergySinkBase, EpEnergyStorageBase
Author: Levente Meszaros
The following diagram shows usage relationships between types. Unresolved types are missing from the diagram.
The following diagram shows inheritance relationships for this type. Unresolved types are missing from the diagram.
Name | Type | Description |
---|---|---|
AlternatingEpEnergyGenerator | simple module |
This energy generator model alternates between two modes called generation and sleep mode. In generation mode it generates a randomly selected constant power for a random time interval. In sleep mode it doesn't generate energy for another random time interval. |
Name | Value | Description |
---|---|---|
display | i=block/plug |
Name | Type | Unit |
---|---|---|
powerGenerationChanged |
Name | Title | Source | Record | Unit | Interpolation Mode |
---|---|---|---|---|---|
powerGeneration | Power generation | powerGenerationChanged | vector | sample-hold |
// // This is an abstract base module for power based energy generator models. // It defines shared signals and statistics. // // @see ~EpEnergyConsumerBase, ~EpEnergySourceBase, ~EpEnergySinkBase, ~EpEnergyStorageBase // @author Levente Meszaros // simple EpEnergyGeneratorBase like IEpEnergyGenerator { parameters: @display("i=block/plug"); @signal[powerGenerationChanged]; @statistic[powerGeneration](title="Power generation"; source=powerGenerationChanged; record=vector; interpolationmode=sample-hold); }